R21xx-HP FlexFabric 11900 FCoE Command Reference

19
Syntax
display fc login [ vsan vsan-id ] [ count ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
vsan vsan-id: Specifies a VSAN by its number in the range of 1 to 3839. If no VSAN is specified, this
command displays the node login information of all VSANs.
count: Displays the total number of logged-in nodes.
Examples
# Display the node login information of VSAN 1.
<Sysname> display fc login vsan 1
Interface VSAN FCID Node WWN Port WWN
Vfc2 1 0x010000 21:01:00:1b:32:a0:fa:18 21:01:00:1b:32:a0:fa:17
# Display the total number of logged-in nodes for each VSAN on the switch.
<Sysname> display fc login count
VSAN Entries
1 1
2 1
3 1
Total entries: 3
# Display the total number of logged-in nodes for VSAN 3.
<Sysname> display fc login vsan 3 count
Total entries: 1
Table 8 Command output
Field Descri
p
tion
Interface Interface on the switch connected to the node.
VSAN VSAN ID.
FCID FC address assigned by the switch to the node.
Port WWN WWN of the port connecting the node to the switch.
display fc name-service database
Use display fc name-service database to display the name server database information.
Syntax
display fc name-service database [ vsan vsan-id [ fcid fcid ] ] [ verbose ]
Views