R21xx-HP FlexFabric 11900 FCoE Configuration Guide

29
Non-disruptive reconfiguration or isolating the switch may be performed. Continu
e? [Y/N]:y
[SwitchA-vsan1] quit
# Create interface VFC 200, configure it to operate in E mode, bind it to interface
Ten-GigabitEthernet 1/0/1, and assign it to VSAN 1 as a trunk port.
[SwitchA] interface vfc 200
[SwitchA-Vfc200] fc mode e
[SwitchA-Vfc200] bind interface ten-gigabitethernet1/0/1
[SwitchA-Vfc200] port trunk vsan 1
[SwitchA-Vfc200] quit
# Configure interface Ten-GigabitEthernet 1/0/1 to allow VLAN 20.
[SwitchA] vlan 20
[SwitchA-Vlan20] quit
[SwitchA] interface ten-gigabitethernet1/0/1
[SwitchA-Ten-GigabitEthernet1/0/1] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/1] port trunk permit vlan 20
[SwitchA-Ten-GigabitEthernet1/0/1] quit
# Create interface VFC 100, configure it to operate in F mode, bind it to interface
Ten-GigabitEthernet 1/0/2, and assign it to VSAN 1 as a trunk port.
[SwitchA] interface vfc 100
[SwitchA-Vfc100] fc mode f
[SwitchA-Vfc100] bind interface ten-gigabitethernet1/0/2
[SwitchA-Vfc100] port trunk vsan 1
[SwitchA-Vfc100] quit
# Configure interface Ten-GigabitEthernet 1/0/2 to allow VLAN 20.
[SwitchA] vlan 20
[SwitchA-Vlan20] quit
[SwitchA] interface ten-gigabitethernet1/0/2
[SwitchA-Ten-GigabitEthernet1/0/2] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/2] port trunk permit vlan 20
[SwitchA-Ten-GigabitEthernet1/0/2] quit
# Enable FCoE for VLAN 20 and map it to VSAN 1.
[SwitchA] vlan 20
[SwitchA-vlan20] fcoe enable vsan 1
2. Configure Switch B:
# Configure Switch B to operate in advanced mode, save the configuration, and reboot Switch B.
(Skip this step if the switch is operating in advanced mode.)
<SwitchB> system-view
[SwitchB] system-working-mode advance
Do you want to change the system working mode? [Y/N]:y
The system working mode is changed, please save the configuration and reboot the
system to make it effective.
# Disable the fabric configuration function and configure Switch B to operate in FCF mode.
<SwitchB> system-view
[SwitchB] fcoe-mode fcf
[SwitchB] vsan 1
[SwitchB-vsan1] undo domain configure enable