R21xx-HP FlexFabric 11900 FCoE Configuration Guide

35
[SwitchD] system-working-mode advance
Do you want to change the system working mode? [Y/N]:y
The system working mode is changed, please save the configuration and reboot the
system to make it effective.
# Enable the fabric configuration function (optional, because this function is enabled by default),
and configure Switch D to operate in FCF mode.
<SwitchD> system-view
[SwitchD] fcoe-mode fcf
[SwitchD] vsan 1
[SwitchD-vsan1] domain configure enable
# Configure the domain ID as 14.
[SwitchD-vsan1] domain-id 14 preferred
Non-disruptive reconfiguration or isolating the switch may be performed. Continu
e? [Y/N]:y
[SwitchD-vsan1] quit
# Enable FCoE for VLAN 10 and map it to VSAN 1.
[SwitchD] vlan 10
[SwitchD-vlan10] fcoe enable vsan 1
[SwitchD-vlan10] quit
# Create interface VFC 1, bind it to interface Ten-GigabitEthernet 4/0/1, configure it to operate
in F mode, and assign it to VSAN 1 as a trunk port.
[SwitchD] interface Vfc 1
[SwitchD-Vfc1] bind interface ten-gigabitethernet4/0/1
[SwitchD-Vfc1] fc mode f
[SwitchD-Vfc1] port trunk vsan 1
[SwitchD-Vfc1] quit
# Create interface VFC 2, bind it to interface Ten-GigabitEthernet 4/0/2, configure it to operate
in E mode, and assign it to VSAN 1 as a trunk port.
[SwitchD] interface Vfc 2
[SwitchD-Vfc2] bind interface ten-gigabitethernet4/0/2
[SwitchD-Vfc2] fc mode e
[SwitchD-Vfc2] port trunk vsan 1
[SwitchD-Vfc2] quit
Verifying the configurations
1. Verify the configurations on Switch A:
# Display the domain information of VSAN 1.
[SwitchA-vsan1] display fc domain vsan 1
Domain Information of VSAN 1:
Running time information:
State: Stable
Switch WWN: 48:33:43:2d:46:43:1A:1A
Fabric name: 48:33:43:2d:46:43:1B:1B
Priority: 128
Domain ID: 11
Configuration information: