R21xx-HP FlexFabric 11900 FCoE Configuration Guide
57
# Enable FSPF globally.
[SwitchB-vsan2] fspf enable
[SwitchB-vsan2] quit
# Enable FSPF for interface VFC 100.
[SwitchB] interface Vfc 100
[SwitchB-Vfc 100] port trunk vsan 2
[SwitchB-Vfc 100] undo fspf silent vsan 2
Verifying the configurations
# Display FSPF neighbor information on Switch A.
[SwitchA-Vfc 100] display fspf neighbor
FSPF neighbor information of VSAN 2(01):
Interface NbrDomain IfIndex NbrIfIndex Dead Time State
Vfc 100 2 0x68 0x68 00:01:06 Full
# Display information about the FC routing table on Switch A.
[SwitchA-Vfc 100] display fc routing-table vsan 2
Routing Table: VSAN 2
Destinations : 5 Routes : 5
Destination/mask Protocol Preference Cost Interface
0x020000/8 FSPF 20 265 Vfc 100
0xfffc01/24 DIRECT 0 0 InLoop0
0xfffffa/24 DIRECT 0 0 InLoop0
0xfffffc/24 DIRECT 0 0 InLoop0
0xfffffd/24 DIRECT 0 0 InLoop0
# On Switch A, use the fcping command to ping Switch B and check whether Switch B is reachable.
[SwitchA-Vfc 100] fcping fcid fffc02 vsan 2
FCPING fcid 0xfffc02: 128 data bytes, press CTRL_C to break.
Reply from 0xfffc02: bytes = 128 time = 1.102 ms
Reply from 0xfffc02: bytes = 128 time = 0.276 ms
Reply from 0xfffc02: bytes = 128 time = 0.253 ms
Reply from 0xfffc02: bytes = 128 time = 0.270 ms
Reply from 0xfffc02: bytes = 128 time = 0.247 ms
--- 0xfffc02 fcping statistics ---
5 packet(s) transmitted
5 packet(s) received
0.00% packet loss
round-trip min/avg/max = 0.247/0.430/1.102 ms
The output shows that Switch A can reach Switch B.