R21xx-HP FlexFabric 11900 FCoE Configuration Guide
78
# Create interface VFC 1, bind it to interface Ten-GigabitEthernet 1/0/1, and configure it to allow VSAN
10.
[SwitchA] interface vfc 1
[SwitchA-Vfc1] bind interface Ten-GigabitEthernet1/0/1
[SwitchA-Vfc1] port trunk vsan 10
# Configure the uplink interface.
[SwitchA-vfc1] fc mode np
[SwitchA-Vfc1] quit
# Create interfaces VFC 1 and VFC 2, bind them to interfaces Ten-GigabitEthernet 1/0/2 and
Ten-GigabitEthernet 1/0/3, respectively, and configure them to allow VSAN 10.
[SwitchA] interface vfc 2
[SwitchA-Vfc2] bind interface Ten-GigabitEthernet1/0/2
[SwitchA-Vfc2] port trunk vsan 10
[SwitchA-Vfc2] quit
[SwitchA] interface vfc 3
[SwitchA-Vfc3] bind interface Ten-GigabitEthernet1/0/3
[SwitchA-Vfc3] port trunk vsan 10
[SwitchA-Vfc3] quit
# Configure the downlink interface.
[SwitchA] interface vfc 2
[SwitchA-vfc 2] fc mode f
[SwitchA-vfc 2] quit
[SwitchA] interface vfc 3
[SwitchA-vfc 3] fc mode f
[SwitchA-vfc 3] quit
# Enable FCoE for VLAN 20 and map it to VSAN 10.
[SwitchA] vlan 20
[SwitchA-vlan20] fcoe enable vsan 10
[SwitchA-vlan20] quit
Verifying the configurations
# Display the nodes on downlink interfaces and their mapped uplink interfaces.
[SwitchA] display npv login
Server External
Interface VSAN FCID Port WWN Node WWN Interface
Vfc2 1 0x010001 20:00:00:15:40:94:00:00 20:00:00:15:40:94:00:00 Vfc1
Vfc3 1 0x010002 20:00:00:42:40:94:00:01 20:00:00:42:40:94:00:01 Vfc1
# Display the status of Switch A.
[SwitchA] display npv status
External Interfaces:
Interface: Vfc1 VSAN tagging mode: Tagging
VSAN State FCID
1 Up 0x010000
Number of External Interfaces: 1
Server Interfaces: