R21xx-HP FlexFabric 11900 FCoE Configuration Guide

82
[SwitchA-Vfc200] port trunk vsan 1
[SwitchA-Vfc200] quit
# Enable the fabric configuration function.
[SwitchB] vsan 1
[SwitchB-vsan1] domain configure enable
# Configure the domain ID as 2.
[SwitchB-vsan1] domain-id 2 static
Non-disruptive reconfiguration or isolating the switch may be performed. Continu
e? [Y/N]:y
[SwitchA-vsan1] quit
# Enable FCoE for VLAN 10 and map it to VSAN 1.
<SwitchA> system-view
[SwitchA] vlan 10
[SwitchA-vlan10] fcoe enable vsan 1
[SwitchA-vlan10] quit
# Configure a static route.
[SwitchB-vsan1] fc route-static 010000 8 Vfc200
Verifying the configurations
Check whether Switch A and Switch B can reach each other.
# On Switch A, use the fcping command to ping Switch B and check whether Switch B is reachable.
[SwitchA-vsan1] fcping fcid fffc02 vsan 1
FCPING fcid 0xfffc02: 128 data bytes, press CTRL_C to break.
Reply from 0xfffc02: bytes = 128 time = 23 ms
Reply from 0xfffc02: bytes = 128 time = 9 ms
Reply from 0xfffc02: bytes = 128 time = 19 ms
Reply from 0xfffc02: bytes = 128 time = 14 ms
Reply from 0xfffc02: bytes = 128 time = 25 ms
--- 0xfffc02 fcping statistics ---
5 packet(s) transmitted
5 packet(s) received
0.00% packet loss
round-trip min/avg/max = 9/18/25 ms