R21xx-HP FlexFabric 11900 Fundamentals Command Reference

109
5 LSU1SUPB9 standby 0 NONE None
6 NONE Absent 0 NONE None
The output shows that the slot number of the standby MPU is 5.
# Access the root directory of the Flash on the standby MPU.
<Sysname> cd slot5#flash:/
# Change to the test folder in the root directory of the active MPU.
<Sysname> cd flash:/test
In IRF mode:
# Display the member IDs and slot numbers of the IRF fabric's MPUs.
<Sysname> display irf
MemberID Slot Role Priority CPU-Mac Description
*+1 4 Master 1 00e0-fc0f-8c05 ---
2 4 Standby 1 00e0-fc0f-8c0f ---
2 5 Standby 1 00e0-fc0f-8c1f ---
--------------------------------------------------
* indicates the device is the master.
+ indicates the device through which the user logs in.
The Bridge MAC of the IRF is: 7425-8a10-4508
Auto upgrade : yes
Mac persistent : always
Domain ID : 0
Auto merge : no
The output shows that the active MPU of the IRF fabric resides in slot 4 of member device 1 and the IRF
fabric has two standby MPUs: one in slot 4 of member device 2, and one in slot 5 of member device 2.
# Access the test folder in the Flash root directory of the IRF fabric's active MPU.
<Sysname> cd flash:/test
# Change to the Flash root directory of the standby MPU that resides in slot 5 of member device 2.
<Sysname> cd chassis2#slot5#flash:/
# Change to the test folder in the Flash root directory of the IRF fabric's active MPU.
<Sysname> cd flash:/
copy
Use copy to copy a file.
Syntax
copy fileurl-source fileurl-dest
Views
User view
Predefined user roles
network-admin