R21xx-HP FlexFabric 11900 Fundamentals Command Reference
216
display environment [ slot slot-number ]
In IRF mode:
display environment [ chassis chassis-number [ slot slot-number ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
chassis chassis-number: Specifies an IRF member device. (In IRF mode.)
slot slot-number: Specifies a card by the number of the slot where the card resides.
Usage guidelines
• If no card is specified, this command displays the temperature statistics for all temperature sensors
on the device. (In standalone mode.)
• If no IRF member device is specified, this command displays the temperature statistics for all
temperature sensors in the IRF fabric. If an IRF member device is specified but no card is specified,
this command displays the temperature statistics for all sensors on the specified IRF member device.
(In IRF mode.)
Examples
# In standalone mode, display the temperature statistics for all temperature sensors on the device.
<Sysname> display environment
System temperature information (degree centigrade):
----------------------------------------------------------------------
Slot Sensor Temperature Lower Warning Alarm Shutdown
1 hotspot 1 43 0 68 80 NA
1 hotspot 2 55 0 88 100 110
2 hotspot 1 43 0 68 80 NA
2 hotspot 2 43 0 68 80 NA
2 hotspot 3 45 0 88 100 110
2 hotspot 4 45 0 88 100 110
3 hotspot 1 43 0 68 80 NA
3 hotspot 2 55 0 88 100 110
4 inflow 1 23 0 48 60 NA
4 hotspot 1 30 0 80 95 NA
# In IRF mode, display the temperature statistics for all temperature sensors in the IRF fabric.
<Sysname> display environment
System temperature information (degree centigrade):
-----------------------------------------------------------------------------
Chassis Slot Sensor Temperature Lower Warning Alarm Shutdown
1 1 hotspot 1 43 0 68 80 NA
1 1 hotspot 2 55 0 88 100 110
1 2 hotspot 1 43 0 68 80 NA
1 2 hotspot 2 43 0 68 80 NA