R21xx-HP FlexFabric 11900 Fundamentals Command Reference

31
Predefined user roles
network-admin
Parameters
speed-value: Transmission rate in bps. The transmission rates available for asynchronous serial interfaces
include: 300 bps, 600 bps, 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400 bps, 57600
bps, and 115200 bps.
Usage guidelines
The configuration terminal and the device must be configured with the same transmission rate to
communicate.
Examples
# Set the transmission rate to 19200 bps for user interface AUX 0.
<Sysname> system-view
[Sysname] user-interface aux 0
[Sysname-ui-aux0] speed 19200
stopbits
Use stopbits to specify the number of stop bits for a character.
Use undo stopbits to restore the default.
Syntax
stopbits { 1 | 1.5 | 2 }
undo stopbits
Default
One stop bit is used.
Views
AUX user interface view
Predefined user roles
network-admin
Parameters
1: Uses one stop bit.
1.5: Uses one and a half stop bits. The device does not support using one and a half stop bits. If you
specify this keyword, two stop bits are used.
2: Uses two stop bits.
Usage guidelines
This command is only applicable to asynchronous serial interfaces, including console ports.
The configuration terminal and the device must be configured to use the same number of stop bits to
communicate.
Examples
# Set the number of stop bits to 1 for user interface AUX 0.
<Sysname> system-view