R21xx-HP FlexFabric 11900 Fundamentals Configuration Guide

155
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Configure the temperature
alarm thresholds.
In standalone mode:
temperature-limit slot slot-number
{ hotspot | inflow } sensor-number
lowerlimit warninglimit [ alarmlimit ]
In IRF mode:
temperature-limit chassis
chassis-number slot slot-number
{ hotspot | inflow } sensor-number
lowerlimit warninglimit [ alarmlimit ]
See Table 15 for the defaults.
The alarm threshold must be
higher than the warning
threshold, and the warning
threshold must be higher than the
lower temperature threshold.
Table 15 Default temperature thresholds
Card
Sensor
t
yp
e
Sensor
ID
Lower
threshold
Warning
threshold
Alarming
threshold
Shutdown
threshold
LSU1SUPB9 (JG609A)
Inflow 1 0°C (32°F)
48°C
(118.4°F)
60°C
(140°F)
N/A
Hotspot
1 0°C (32°F)
80°C
(176°F)
95°C
(203°F)
N/A
LSU1FAB08D9 (JG610A)
Hotspot
1, 2 0°C (32°F)
68°C
(154.4°F)
80°C
(176°F)
N/A
3, 4 0°C (32°F)
88°C
(190.4°F)
100°C
(212°F)
110°C
(230°F)
LSU1TGS48SF9 (JG612A) Hotspot
1-2 0°C (32°F)
68°C
(154.4°F)
80°C
(176°F)
N/A
3-5 0°C (32°F)
88°C
(190.4°F)
100°C
(212°F)
110°C
(230°F)
Other SF card (for example,
LSU1QGS4SF9 (JG613A),
LSU1QGS8SF9 (JG614A),
and
LSU1TGS32SF9(JG611A))
Hotspot
1 0°C (32°F)
68°C
(154.4°F)
80°C
(176°F)
N/A
2 0°C (32°F)
88°C
(190.4°F)
100°C
(212°F)
110°C
(230°F)
Specifying a traffic load sharing mode for an LPU
The HP FlexFabric 11900 switch series supports load sharing for upstream traffic among LPUs. You can
specify different traffic load sharing modes for different purposes.
Load sharing is available for only unicast traffic.
To specify a traffic load sharing mode for an LPU:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A