R21xx-HP FlexFabric 11900 Fundamentals Configuration Guide
36
Ste
p
Command
Remarks
5. Create an
SNMPv3 user.
snmp-agent usm-user v3 user-name
group-name [ remote { ip-address | ipv6
ipv6-address } [ vpn-instance
vpn-instance-name ] ] [ { cipher | simple }
authentication-mode { md5 | sha }
auth-password [ privacy-mode { aes128 |
des56 } priv-password ] ] [ acl acl-number | acl
ipv6 ipv6-acl-number ] *
To send informs to an SNMPv3
NMS, you must use the remote
ip-address option to specify the IP
address of the NMS.
Configuring SNMPv1 or SNMPv2c access
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enable the SNMP
agent.
snmp-agent
By default, the SNMP agent is
disabled.
3. (Optional.) Create or
update MIB view
information.
snmp-agent mib-view { excluded |
included } view-name oid-tree [ mask
mask-value ]
By default, the device has four views,
all of which are named ViewDefault:
• View 1 includes MIB subtree iso.
• View 2 does not include subtree
snmpUsmMIB.
• View 3 does not include subtree
snmpVacmMIB.
• View 4 does not include subtree
snmpModules.18.
4. Configure the SNMP
access right.
• (Method 1) Specify the SNMP NMS
access right directly by configuring
an SNMP community:
snmp-agent community { read |
write } community-name [ mib-view
view-name ] [ acl acl-number | acl
ipv6 ipv6-acl-number ] *
• (Method 2) Configure an SNMP
group and add a user to the SNMP
group:
a. snmp-agent group { v1 | v2c }
group-name [ read-view
view-name ] [ write-view
view-name ] [ notify-view
view-name ] [ acl acl-number |
acl ipv6 ipv6-acl-number ] *
b. snmp-agent usm-user { v1 |
v2c } user-name group-name
[ acl acl-number | acl ipv6
ipv6-acl-number ] *
Use either method.
The username for method 2 is
equivalent to the community name for
method 1, and must be the same as
the community name configured on
the NMS.
By default, no SNMP group or SNMP