[SwitchC-Vlan-interface102] quit
[SwitchC] interface tunnel 0
[SwitchC-Tunnel0] pim dm
[SwitchC-Tunnel0] quit
5. On Switch C, configure a static multicast route, specifying the RPF neighbor toward the source as
interface Tunnel 0 on Switch A.
[SwitchC] ip rpf-route-static 50.1.1.0 24 50.1.1.1
Verifying the configuration
The source sends the multicast data to the multicast group 225.1.1.1 and the receiver host can receive the
multicast data after joining the multicast group. You can use the display pim routing-table command to
display PIM routing table information. For example:
# Display PIM routing table information on Switch C.
[SwitchC] display pim routing-table
Total 1 (*, G) entry; 1 (S, G) entry
(*, 225.1.1.1)
Protocol: pim-dm, Flag: WC
UpTime: 00:04:25
Upstream interface: NULL
Upstream neighbor: NULL
RPF prime neighbor: NULL
Downstream interface(s) information:
Total number of downstreams: 1
1: Vlan-interface200
Protocol: igmp, UpTime: 00:04:25, Expires: never
(10.1.1.100, 225.1.1.1)
Protocol: pim-dm, Flag: ACT
UpTime: 00:06:14
Upstream interface: Tunnel0
Upstream neighbor: 50.1.1.1
RPF prime neighbor: 50.1.1.1
Downstream interface(s) information:
Total number of downstreams: 1
1: Vlan-interface200
Protocol: pim-dm, UpTime: 00:04:25, Expires: never
The output shows that Switch A is the RPF neighbor of Switch C and the multicast data from Switch A is