R21xx-HP FlexFabric 11900 MPLS Command Reference

Table Of Contents
178
Field Descri
p
tion
Drop Unknown
Indicates whether the VSI drops packets with unknown source MAC addresses
when the MAC table limit is reached (not supported).
State PW state: Up, Down, Blocked, or BFD Defect.
AC AC type: Layer 2 interface and service instance, such as XGE1/0/3 srv1.
Related commands
vsi
encapsulation
Use encapsulation to configure match criteria for a service instance.
Use undo encapsulation to remove match criteria for a service instance.
Syntax
encapsulation s-vid vlan-id [ only-tagged ]
encapsulation default
encapsulation { tagged | untagged }
undo encapsulation
Default
No match criteria are configured for a service instance.
Views
Service instance view
Predefined user roles
network-admin
Parameters
s-vid vlan-id: Matches incoming packets with an outer VLAN ID in the range of 1 to 4094.
only-tagged: Matches only tagged incoming packets. If this keyword is not specified when the matching
VLAN is the default VLAN, packets with the default VLAN ID or without any VLAN ID are all matched. If
this keyword is specified when the matching VLAN is the default VLAN, only packets with the default
VLAN ID are matched.
default: Specifies the default match criteria, which accepts all incoming packets.
tagged: Matches tagged incoming packets.
untagged: Matches untagged incoming packets.
Usage guidelines
You can choose only one of the following match criteria for a service instance:
Match all incoming packets.
Match incoming packets with any VLAN ID or no VLAN ID.
Match incoming packets with a specific VLAN ID.