Usage guidelines
When you execute this command for a client in registered state, the OAP manager sends a restart
notification to the specified OAP client, and the client restarts after receiving the notification. If you
execute this command for a non-existent client, an error message appears.
Client IDs are assigned by the OAP manager to OAP clients to uniquely identify the clients.
Examples
# Restart OAP client 1.
<Sysname> system-view
[Sysname] oap client reboot 1
Related commands
oap client close
oap enable
Use oap enable to enable OAP.
Use undo oap enable to disable OAP.
Syntax
oap enable
undo oap enable
Default
OAP is disabled on an interface.
Views
Layer 2 Ethernet interface view, Layer 2 aggregate interface view, Layer 3 Ethernet interface view
Predefined user roles
network-admin
Examples
# Enable OAP on interface Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] oap enable
oap timer clock-sync
Use oap timer clock-sync to set the clock synchronization timer.
Use undo oap timer clock-sync to restore the default.
Syntax
oap timer clock-sync minutes
undo oap timer clock-sync
Default
The clock synchronization timer is set to 5 minutes.