R21xx-HP FlexFabric 11900 OAA Command Reference
3
Views
System view
Predefined user roles
network-admin
Parameters
minutes: Specifies the clock synchronization timer value in minutes, in the range of 0 to 1440. Setting this
argument to 0 disables clock synchronization.
Usage guidelines
The clock synchronization timer regularly triggers the OAP manager to send clock and time zone
synchronization notifications to OAP clients so the clients' clocks keep synchronized to the manager's
clock.
Examples
# Set the clock synchronization timer to 20 minutes.
<Sysname> system-view
[Sysname] oap timer clock-sync 20
oap timer monitor
Use oap timer monitor to set the client monitoring timer.
Use undo oap timer monitor to restore the default.
Syntax
oap timer monitor seconds
undo oap timer monitor
Default
The client monitoring timer is set to 5 seconds.
Views
System view
Predefined user roles
network-admin
Parameters
seconds: Specifies the client monitoring timer in seconds, in the range of 0 to 10. Setting this argument
to 0 disables client monitoring.
Usage guidelines
The client monitoring timer regularly triggers the OAP manager to send client monitoring packets to OAP
clients.
Examples
# Set the client monitoring timer to 6 seconds.
<Sysname> system-view
[Sysname] oap timer monitor 6