Troubleshooting214
Encountering errors when
performing LUN management
on HDS 9980 V systems.
The host domains on this HDS 9980 V must be
reconfigured using the native software before can
manage the LUNs. The same LUN or host port is
included in two host domains on the same port.
The HDS 9980 V, in conjunction with HiCommand
Server 2.4, supports a new feature, which is not yet
supported in 4.2.
This new feature allows you to create multiple host
domains on the same storage port, which include
the same LUNs or host ports.
4.2 only supports the previous HDS V series
configuration rules.
For each storage port, any given LUN can only be a
member of a single host storage domain. For each
storage port, any given host port can only be a
member of a single host storage domain.
To manage your 9980 V LUNs with 4.2, any
preexisting host domains that do not conform to
these two rules, must be reconfigured or removed
using the HiCommand Server 2.4 or greater.
When the rules are met, 4.2 will discover all the
host domains and allow you to configure them.
If rules 1 & 2 are not met, 4.2 can discover all the
LUNs, and their host assignments.
The data displayed in the LUNs and Hosts tables
will be correct.
The Troubleshoot tab can be used to diagnose the
connectivity between LUNs and host ports.
The host domain data will be incomplete. Therefore,
the dialog will be in a browse only mode.
No actions can be taken on a HDS 9980 V that has
been configured in this way until its host storage
domains are reconfigured to meet rules 1 and 2
above.
Table 26 Address problems and resolutions (continued)
Problem Resolution