GbE2c Ethernet Blade Switch for HP c-Class Quick Setup Instructions

Item Description
1 Reset button
2 Health LED
Off—Not powered up
Green—Powered up and all ports match
Amber—Indicates a problem such as a port
mismatch. For more information, see the HP
BladeSystem enclosure setup and installation guide.
3 UID LED
4 DB-9 management serial port
5 RJ-45 ports 20 - 24
CAUTION: Pressing the Reset button while the Health
LED is green resets the interconnect switch.
Planning the interconnect
switch configuration
The interconnect switch ships with a default configuration in
which all downlink and uplink ports are enabled and
assigned a default VLAN with a VLAN ID (VID) equal to 1.
The interconnect ports (17 and 18) are disabled. This default
configuration simplifies your initial setup. Your environment
might require other configurations. For more information
about planning the interconnect switch configuration, see the
GbE2c Ethernet Blade Switch for HP c-Class User Guide
located on the HP website
(http://www.hp.com/go/bladesystem/documentation
).
The interconnect switch does not affect or determine NIC
numeration and the associated mapping of NIC interfaces to
interconnect switch ports. The numbering of the NICs on the
server (for example, NIC 1, NIC 2, NIC 3) is determined by
the server type, the server operating system, and what NICs
are enabled on the server.
The Onboard Administrator controls all port enabling.
Enabling is based on matching ports between the server and
the I/O switch bay. Before power up, the Onboard
Administrator verifies that the server NIC option matches the
switch bay that is selected and enables all ports for the NICs
installed.
For detailed port mapping information, see the HP
BladeSystem enclosure installation poster or the HP
BladeSystem enclosure setup and installation guide on the HP
website
(http://www.hp.com/go/bladesystem/documentation
).
Installing the interconnect
switch
CAUTION: Do not cable the switch until after
configuration.
IMPORTANT: Make sure that the server NIC
configuration matches the switch bay selected.
NOTE: When installing two switches, there are two
switch interconnect ports between adjacent I/O bays.
These ports (17 and 18) are disabled by default. The
ports must be manually enabled to use.
A successful installation is indicated by a green Health LED. If
the Health LED is amber or power is not applied to the switch,
then see the "Troubleshooting" section of the BladeSystem
Enclosure User Guide for more information.