100 Chapter 4: VLANs BMD00113, September 2009
2. Configure the VLANs and their member ports. Since all ports are by default configured for
VLAN 1, configure only those ports that belong to other VLANs.
3. The external Layer 2 switches should also be configured for VLANs and tagging.
>> /cfg/l2/vlan 3
>> VLAN 3# add 2
Current ports for VLAN 3: empty
Pending new ports for VLAN 3: 2
>> VLAN 3# add 4
Current ports for VLAN 3: 2
Pending new ports for VLAN 3: 4
>> VLAN 3# add 17
Current ports for VLAN 3: 2, 4
Pending new ports for VLAN 3: 17
>> VLAN 3# add 18
Current ports for VLAN 3: 2, 4, 17
Pending new ports for VLAN 3: 18
>> VLAN 3# add 21
Current ports for VLAN 3: 2, 4, 17, 18
Pending new ports for VLAN 3: 21
>> /cfg/l2/vlan 4
>> VLAN 4# add 2
Current ports for VLAN 4: empty
Pending new ports for VLAN 4: 2
>> VLAN 4# add 21
Port 21 is an UNTAGGED port and its current PVID is 1.
Confirm changing PVID from 1 to 4 [y/n]: y
Current ports for VLAN 4: 2
Pending new ports for VLAN 4: 21
>> apply (Apply the port configurations)