BLADE OS™ Application Guide HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Version 5.1 Advanced Functionality Software

Table Of Contents
BLADE OS 5.1 Application Guide
36 Chapter 1: Accessing the Switch BMD00113, September 2009
SNMPv2 Trap Host Configuration
The SNMPv2 trap host configuration is similar to the SNMPv1 trap host configuration. Wherever
you specify the model, use snmpv2 instead of snmpv1.
c/sys/ssnmp/snmpv3/usm 10 (Configure user named “v2trap”)
name "v2trap"
/c/sys/ssnmp/snmpv3/access 10 (Define access group to view SNMPv2 traps)
name "v2trap"
model snmpv2
nview "iso"
/c/sys/ssnmp/snmpv3/group 10 (Assign user to the access group)
model snmpv2
uname v2trap
gname v2trap
/c/sys/ssnmp/snmpv3/notify 10 (Assign user to the notify table)
name v2trap
tag v2trap
/c/sys/ssnmp/snmpv3/taddr 10 (Define an IP address to send traps)
name v2trap
addr 47.81.25.66
taglist v2trap
pname v2param
/c/sys/ssnmp/snmpv3/tparam 10 (Specify SNMPv2 traps to send)
name v2param
mpmodel snmpv2c
uname v2trap
model snmpv2
/c/sys/ssnmp/snmpv3/comm 10 (Define the community string)
index v2trap
name public
uname v2trap