BLADE OS™ Command Reference HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1 Advanced Functionality Software
BLADE OS 5.1 Command Reference
372
Chapter 6: The Configuration Menu BMD00114, August 2009
rlimit <-2147483647 - 2147483647>
Configures the rising threshold for the sampled statistic. When the current sampled value is
greater than or equal to this threshold, and the value at the last sampling interval was less than
this threshold, a single event is generated.
flimit <-2147483647 - 214748364)
Configures the falling threshold for the sampled statistic. When the current sampled value is
less than or equal to this threshold, and the value at the last sampling interval was greater than
this threshold, a single event is generated.
revtidx <1-65535>
Configures the rising alarm event index that is triggered when a rising threshold is crossed.
fevtidx <1-65535>
Configures the falling alarm event index that is triggered when a falling threshold is crossed.
owner <1-127 characters>
Enter a text string that identifies the person or entity that uses this alarm index.
delete
Deletes the selected RMON Alarm index.
cur
Displays the current RMON Alarm parameters.
Table 213 RMON Alarm Menu Options (/cfg
/rmon/alarm) (continued)
Command Syntax and Usage