BLADE OS™ ISCLI Reference HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1 Advanced Functionality Software
BLADE OS 5.1 ISCLI Reference
BMD00115, August 2009 Chapter 4: Configuration Commands
255
Forwarding Database Configuration
Use the following commands to configure the Forwarding Database (FDB).
[no] spanning-tree stp <STG number> edge
Enables or disables this port as an edge port. An edge port is not connected to a bridge, and
can begin forwarding traffic as soon as the link is up. Configure server ports as edge ports
(enabled).
Command mode: Interface port
spanning-tree stp <STG number> enable
Enables STG on the port.
Command mode: Interface port
no spanning-tree stp <STG number> enable
Disables STG on the port.
Command mode: Interface port
show interface port <port number> spanning-tree stp <STG number>
Displays the current STG port parameters.
Command mode: All
Table 144 FDB configuration commands
Command Syntax and Usage
mac-address-table aging <0-65535>
Configures the aging value for FDB entries, in seconds. The default value is 300.
Command mode: Global configuration
show mac-address-table
Display current FDB configuration.
Command mode: All except User EXEC
Table 143 Spanning Tree Port Commands
Command Syntax and Usage