BLADE OS™ ISCLI Reference HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1 Advanced Functionality Software
BLADE OS 5.1 ISCLI Reference
BMD00115, August 2009 Chapter 4: Configuration Commands
271
Failover Manual Monitor - Control Configuration
Use this menu to define the port link(s) to control.
The Manual Monitor - Control configuration accepts downlink and uplink ports, but not
management ports.
Table 159 Failover Manual Monitor - Control commands
Command Syntax and Usage
failover trigger <1-8> mmon control member <port number>
Adds the selected port to the Manual Monitor - Control.
Command mode: Global configuration
no failover trigger <1-8> mmon control member <port number>
Removes the selected port from the Manual Monitor - Control.
Command mode: Global configuration
show failover trigger
Displays the current Failover settings.
Command mode: All except User EXEC