Server Link Failure Detection Configuration
Server Link Failure Detection (SFD) allows the switch to monitor specific downlink ports to detect
server link failures. When all of the server links in the Link to Monitor (LtM) fail, the switch
enables the interconnect ports.
The following table describes the Server Link Failure Detection (SFD) Configuration Menu
options.
SFD Link to Monitor Configuration
The following table describes the Link to Monitor (LtM) Menu options. The LtM can consist of
only downlink ports (1-16) or a single trunk containing only downlink ports.
Table 210 Server Link Failure Detection (SFD) commands
Command Syntax and Usage
sfd enable
Globally turns on Server Link Failure Detection.
no sfd enable
Globally turns off Server Link Failure Detection.
show sfd
Displays the current SFD configuration parameters.
Table 211 SFD Link to Monitor commands
Command Syntax and Usage
sfd ltm port <port number>
Adds a port to the LtM. Only downlink ports (1-16) are allowed in the SFD LtM.
no sfd ltm port <port number>
Removes a port from the LtM.
sfd ltm portchannel <trunk number>
Adds a trunk group to the LtM. The LtM trunk group can contain only downlink ports (1-16).
no sfd ltm portchannel <trunk number>
Removes a trunk group from the LtM.