ATM Configuration and Troubleshooting Guide
Troubleshooting
Before You Begin Troubleshooting
Chapter 9 179
Step 10. If your adapter has an SMF or MMF interface, disconnect the cable.
Using a special, commercially-available cleaning kit, clean the adapter
sockets and the cable plugs. Reconnect the cable. Wait for 10 minutes
before checking if the problem persists.
When troubleshooting network connections, you must also check the
switch and the remote end system. Use the troubleshooting tools and
procedures provided with the switch and the remote end system’s ATM
adapter to check for and eliminate any problems in these components.
Be sure that the Internet Services are working correctly on both the local
and remote systems. See Installing and Administering Internet Services
for more information.