ATM Release Notes

ATM Version I.11.11.30
Known Problems and Workarounds
Chapter 334
Known Problems and Workarounds
The known problems and corresponding workarounds for version K.11.11.10 of the ATM link
software on HP-UX 11i are as follows:
For those wishing to use OLAR, your system may need to update its firmware. For
additional details, please refer to the Readme Before Installing or Updating to HP-UX 11i
document provided with your HP product.
On HP VISUALIZE UNIX B1000, C3000, J5000, and J7000 Workstations, if you are
running a firmware version earlier than 3.2, the A5513A and A5515A HP-PCI ATM/155
adapters do not work if they are installed in the 66 MHz slots of those workstations (slot 2
of the B1000 and C3000, and slots 4 and 7 of the J5000 and J7000). The adapters do work
if they are installed in the 33 MHz slots of those workstations.
Workaround: Install B1000/C3000/J5000/J7000 firmware version 3.2 or later. The
firmware version 3.2 is available as firmware patch PF_CBCJ0032 (contact your
Hewlett-Packard representative for patch installation information). After the firmware is
installed, the adapters will work in any of the PCI slots in the B1000, C3000, J5000, and
J7000 workstations. Instructions for checking the firmware revision number are provided
in the workstation owner’s guide (interrupt the boot process and enter the command IN
-FV at the main menu of the boot console).
If you are using a Nortel Centillion ATM switch that has a software version earlier than
4.0, you will most likely experience interoperability problems (see Nortel support
reference number CR 80877).
Workaround: Upgrade your Nortel Centillion switch to software version 4.0 or later.
Installation error when installing EMS on a system where the Japanese version of EMS is
already installed.
The error messages that are generated are as follows:
ERROR: The EMS (B5736BA) and EMS Japanese (B5736BJ)
products cannot be selected together. Exit swinstall,
and run it again - this time only marking and installing
one or the other.
ERROR: The "checkinstall" script for "EMS-Config" failed (exit code
"1"). The script location was
"/var/tmp/AAAa02046/catalog/EMS-Config/pfiles/checkinstall".
* This script had errors and the execution of this product
cannot proceed until the problem is fixed. Check the above
output from the script for further details.