HP X.25 Release Notes HP-UX 11i v3 Manufacturing Part Number: 5992-4666 September 2008 © Copyright 2008 Hewlett-Packard Development Company, L.P.
Legal Notices Copyright 2008 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license required from HP for po session, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
1 HP X.25 Release Notes This document contains the most recent product information pertaining to X.25 version B.11.31.02, which is supported on the HP-UX 11i v3 operating system.
HP X.
HP X.25 Release Notes Announcement Announcement This revision of X.25 software, J2793B (B.11.31.02) is supported on systems running HP-UX 11i v3 operating system. The X.25 link implements the CCITT X.25 recommendations and contains the components necessary to connect an HP Integrity system to a public or private packet switching network conforming to the CCITT X.25 recommendation (1980, 1984 or 1988), or to another system in a back-to-back configuration.
HP X.25 Release Notes What Is in This Version What Is in This Version This release of X.25 includes only defect fixes and does not contain any new feature. For information on the defect fixes included in this version of X.25, see “Defect Fixes in This Version” on page 10. IMPORTANT X.25 on Integrity servers may generate an MCA on the RS-530/RS-449 interface of an RAD switch. For additional details see, “Known Problems and Workarounds” on page 7. Hardware Overview This version of X.25 (B.11.31.
HP X.25 Release Notes Known Problems and Workarounds Known Problems and Workarounds Problem If you use an HP X.25 2-port PCI card (product number J3525A) in some of the Integrity servers, the system may generate a Machine Check Abort (MCA). This problem may occur if the setup includes the following: • The X.25 card is installed in one of the following HP Integrity servers: — Superdome sx2000 — HP Integrity server rx7640 — HP Integrity server rx8640 • Any version of the HP X.
HP X.25 Release Notes Known Problems and Workarounds Figure 1-1 Inserting a mini-adapter between the X.25 switch and cable connector Figure 1-2 shows how to attach the adapter to the cable connector.
HP X.25 Release Notes Known Problems and Workarounds You can order this special adapter from CAMI Research Inc. The part-number is 902H. For more information, visit the CAMI Research Inc. Web site at: http://www.camiresearch.com/hpux You can also contact CAMI Research Inc. at the following address: CAMI Research Inc. ATTN: Christopher E. Strangio 530 Main Street Suite 2 Acton, MA 01720 USA Tel: +1 978-266-2655 Fax: +1 978-266-2658 e-mail: chris@camiresearch.
HP X.25 Release Notes Defect Fixes in This Version Defect Fixes in This Version Table 1-1 lists the fixes for this release of X.25. Table 1-1 Defect Fixes Identifier Problem QXCR1000584984 The PSI PCI card (J3525A) is displayed as UNCLAIMED and is not usable when the ioscan command is run on a system, after installating SNA. QXCR1000586033 The X.25 client application that attempts to connect to an X.
HP X.25 Release Notes Software Availability in Native Languages Software Availability in Native Languages This version of X.25 is available only in English.
HP X.