HP X.25/9000 Release Notes (June 2007)
HP X.25 Release Notes
Patches and Fixes in This Version
Chapter 1 15
8606359693 With Flow Control Negotiation turned on, incoming flow control facility
status (off) was ignored and ACC/X25 fails to fall back to the default
un-negotiated values.
8606359695 padem(1) does not create log files with appropriate permissions.
8606359698 x25init(1M) may fail while configuring a J3526A card with the
following message:
[x25init] Downloading X.25 interface ....
[x25init] nc open of module wan_7c failed
CAUSE : Command has returned a bad exiting value
ACTION : Contact your system administrator
[x25init] Starting the X.25 stack failed.
8606331586 The Closed User Group (CUG) facility code is always delivered in
Extended format.
8606275401 connect() request on the X.25 socket returns ECONNREFUSED instead
of ENOSPC when all the virtual circuits are already in use.
8606275816 When CARD_RESET diag ioctl is sent to reset the J3525 card, the
j3525_F_ioctl function responsible for this does not handle the spinlock
release properly, creating a spinlock deadlock situation
8606283659 X29 services sends SIGUSR2 to the wrong processes.
8606284304 When a user tries to connect and remove the cable from J3526A (4-port
card) repeatedly, the card fails to detect the status of cable when heavy
traffic is passing through the card.
8606289433 The PAD emulator results in memory leak when handling multiple
connections.
8606289591 x25 interface was stopped and on re-starting it, the system crashed.
Any subsequent attempt to start up the interface has lead to a system
crash.
8606295310 Resource consumption by Padem has increased.
8606133376 There is a typographical error in the "x25check" manpage.
"STRMSGSZ" has been spelled wrongly as "STRMSGZ".
Table 1-5 Fixes (Continued)
SR Number Description