HP X.25/9000 User's Guide HP-UX 11i v3 (5900-1523, August 2011)

Table 28 X.28 PAD command set (continued)
DescriptionPAD Command Set
Resets a virtual circuit (VC). When a VC is reset, all data received (but unread) is lost,
and all X.3 parameters are set to the default values (as they were defined before the VC
was established).
reset
Sets the X.3 parameter n to value v. If there is a syntax error, padem responds with an
ERR service signal and updates the diagnostic text. All changes take effect when a new
VC is established, or immediately if one is already established.
set n:v [,n:v]
Sets the X.3 parameter n to value v and displays the current setting of all parameters.
This command is a combination of the set and par? commands.
set? n:v [,n:v]
Displays status information of a VC. padem responds with FREE” if no VC is established
or with “ENGAGED” if there is a VC established.
stat
Performs a virtual call to the remote host defined by its X.121 address.
x121_address[subaddress] can be replaced with “|symad|” where symad is
[r,g[n[n]]-]
x121_address
defined in the file /etc/x25/x29hosts. P specifies the packet size negotiation. D
specifies the Call User Data (CUD).
[subaddress]
[P/Dd..d
Extended command set
Table 29 Extended command set
DescriptionExtended Command Set
Lists all profile IDs known to padem. The profile IDs are contained in the x3config file.aprof
Displays a complete list of all padem commands with a short description of each.help
Displays or sets the programmatic access name of the interface to which padem is (or will
be) connected.
If this command is entered with a programmatic access name specified in string, padem
sets the programmatic access name for the interface. If the command is entered and
string is not specified, padem displays the programmatic access name for the interface.
ifname [string]
Lists all symbolic names for remote hosts that are accessible to the user. The symbolic
reference names are contained in the /etc/x25/x29hosts file.
list
Displays the last loaded profile ID.lprof
Terminates padem. If the SVC is still connected, it is cleared.quit
Suspends padem for s seconds (maximum 3600).sleep s
Puts padem in verbose display mode. When padem operates in verbose display mode,
it displays CAUSE, EFFECT, and ACTION messages in addition to the standard diagnostic
message.
verbose
NOTE: Certain parameters may be changed automatically during the session as a result of PTY
reconfigurations by the application at the other side of the connection. These changes will
temporarily alter the original defaults set by the PAD Services. The PAD terminal user may also
change PAD parameters at any time with X.28 commands. However, this may result in unpredictable
behavior from the application being processed.
Configuring X.3 profile parameters
X.3 PAD parameters are used to specify how certain I/O operations are performed between Data
Terminal Equipment (DTE) and the remote host PAD. These parameters are used to ensure that the
local DTE and the remote PAD use the same communications profile.
Configuring X.3 profile parameters 111