HP X.25/9000 User's Guide HP-UX 11i v3 (5900-1523, August 2011)
DescriptionX.3 Parameter
Specifies the number of printing characters to be transmitted before the PAD inserts a
carriage return in the data stream. This parameter is not needed on terminals with
auto-wrap-around. The range is 0 through 255.
10 - Chars per Line/Wrap
-Around
This parameter specifies the terminal access speed (Baud rate). x29server does not
allow users to change the Baud rate. It defaults to the terminal Baud rate, which is usually
9600. The possible values and their associated Baud rates are listed below.
11 - Baud
Baud RateValue
1100
134.51
3002
12003
6004
755
1506
18007
2008
1009
5010
75 from terminal, 1200 to terminal11
240012
480013
960014
1920015
4800016
5600017
6400018
DescriptionX.3 Parameter
Specifies whether the terminal can control the flow of data from the PAD to the terminal.
0 indicates no flow control by the terminal, and 1 indicates that flow control by the terminal
may be used.
12 - Flow Control
Specifies whether the PAD inserts a line feed when a carriage return is detected. The
possible values are shown below.
13 - Line Feed
DescriptionValue
Line feed inserted after carriage return in data stream to the terminal.1
Line feed inserted after carriage return in data stream from the terminal.2
Line feed inserted after carriage return when echoed to the terminal.4
X.3 Parameter descriptions 115