IEther-00 (iether) B.11.31.1303.01 Ethernet Driver Release Notes (Edition 3, June 2013)
• PCI OLRAD
• PCI Error handling and recovery
• vPars V6
• HP Integrity Virtual Machines (HPVM)
• HPVM AVIO
• HP-UX LAN provider
• MIB and driver statistics
• Configurable using SMH or nwmgr
• nettl tracing/logging
3 New and changed features in this release
3.1 New features
There are no new features included in this version of IEther-00 at the time of this publication.
3.2 Changed features
The iether driver has been enhanced with performance and stability improvements.
4 Problems fixed in this or earlier versions
4.1 Problems fixed in this version
This release introduces the following defect fixes:
Table 1 HP-UX 11i v3 March 2013 fixes — IEther-00 B.11.31.1303.01
DescriptionSR number
On server blades with 2-port NC364m/445978-B21 and 4-port NC360m/447883-B21
PCIe mezzanine 1GbE adapters, with APA aggregation configured on ports connected to
QXCR1001259174
an external switch, if a user changes the external switch status from UP to DOWN or vice
versa, a system panic occurs. The following panic string is seen:
'wait_for_lock: Already owns lock: lan:iether_hw_lockp '
This occurs in rare circumstances and only on the specific adapters noted.
4.2 Problems fixed in previous releases
Table 2 HP-UX 11i v3 March 2013 fixes — IEther-00 B.11.31.1303
DescriptionSR number
Link timeout to PCIe device with Superdome 2 XFabric failover.QXCR1001233383
This problem was reported on Superdome2 servers, involving PCIe dual-port LAN controller
chips (AD221A, AD222A, and AD393A adapters). An error on the Superdome 2 XFabric
link immediately causes a fabric failover from that link to the redundant path. Transmissions
that were in process on the failing link are replayed along the redundant path. During Crossbar
Fabric failovers, an I/O adapter could encounter a completion timeout (CTO) for transactions
being transmitted at the instant of failover. In such a scenario, the adapter might be declared
as defective although it is performing well. The CTO value on the affected I/O adapters is
not high enough to account for the XFabric failover time.
4