Compaq ProLiant Cluster HA/F500 Administrator Guide
Setting Up the ProLiant Cluster HA/F500 with Hubs
2-14 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:48 PM
2. Click on the tabs of the Controller Properties screen to confirm that the values
in Table 2-4 are set.
Table 2-4: Controller Properties
Tab Name Values
General Allocation class: 0
SCSI version: SCSI-2 or SCSI-3
Host Ports Host Port 1 Requested Topology: Loop Hard
Host Port 1 Actual Topology: Loop Hard
Host Port 1 Requested Port Address: 71
Host Port 1 Actual Port Address: 71
Host Port 2 Requested Topology: Offline
Host Port 2 Actual Topology: Offline
Cache Cache flush time (seconds): 10
Respond to internal cache battery condition:
selected
Command Console LUN SCSI-2 mode—Confirm that the screen is
grayed out (disabled); if not, return to the
“Disabling the Command Console LUN” section.
SCSI-3 mode—Command Console LUN will be
LUN 0 and cannot be disabled.
Connections Operating System: WINNT
Unit Offset: 0 for Port 1
Battery Confirm that the battery is fully charged.
3. Click OK to close the Controller Properties window.