Compaq ProLiant Cluster HA/F500 Administrator Guide
Setting Up the ProLiant Cluster HA/F500 with Hubs
2-26 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:48 PM
Compaq has worked directly with several application vendors throughout the
development of ProLiant Clusters. As a result of these efforts, Compaq has provided
a number of integration documents to assist you with installing these applications in a
ProLiant Cluster environment.
Integration documents are available at
www.compaq.com/highavailability.
Setting Up Dual Storage Controllers
This section describes how to convert a system from a single-adapter, single-storage
controller configuration to a single-adapter, dual-storage controller configuration.
Dual controller configuration allows failover to occur between the controllers in the
event of a controller failure.
Hardware Setup
To set up the hardware:
1. Click Start on the taskbar.
2. Select Programs, Command Console, CLI Window.
3. Click CLI Window to display the Connection Selection dialog box.
4. Select Serial and click OK to display the Connect Serial dialog box.
5. Select the COM port (the port to which the storage controller is connected).
6. Select a baud rate of 9600.
7. Click Connect to display the CLI window.
8. Press Enter to initialize communications.
9. Type the following command and press Enter:
shutdown this_controller
10. Close the CLI window.
11. Shut down and power off both host servers.
12. Power off the storage subsystem.