HP StorageWorks HA-Fabric Manager Release Notes, V08.08.00 (AA-RUR6H-TE, December 2005)

Which LAN is to be the private LAN for communication between the HAFM
appliance, and the Directors and Edge Switches that the HAFM appliance
manages?
Which LAN is to be the public LAN for communication between the HAFM
appliance and computers seeking remote client access to the HAFM appliance?
The issue arises because either LAN connection on the HAFM appliance can be the
public LAN or the private LAN. Though the Directors and Edge Switches can be
managed via either LAN, the public LAN is the only one that can suppor t remote client
access. Thus, if one attempts to access the HAFM appliance via a remote client session
and is unknowingly using what has been designated as the private LAN, the remote
session is not allowed. The IP address that the HAFM appliance has determined to be
thepublicLANwhichsupportsremoteclientaccess,displaysHAFMwhichdisplays
after selecting SAN > Server Properties.
HAFM designates the public LAN as the rst LAN detected whose IP address is not the
reserved private subnet 10.x.x.x. Thus, if neither IP address is 10.x.x.x,therst
L AN detected by HAFM is designated as the public LAN. This order of detection is
inuenced by Microsoft Windows and is not guaranteed.
For a dual LAN conguration, both LANs must be connected when the HAFM
appliance is booted up. If only one is connected, HAFM interprets this as a s ingle
LAN conguration, and the connected LAN is designated as the LAN for remote client
sessions.
Workaround
There are
two ways to ensure the public and private designations of the LANs.
If you use a private L A N IP address, this causes this LAN to be designated as
the private L AN. You must also have the public LA N connection active when the
HAFM app
liance is booting up, or else HAFM interprets this as a single LAN
connect
ion cong uration, and the 10.x.x.x LAN is designated as the LAN for
remote client sessions.
You can congure a specied Ethernet interface on the HAFM appliance to be
the public L AN (to listen for remote client connections). To con gure this feature,
you must manually edit a le on the HAFM appliance to explicitly specify which
IP add
ress HAFM should use as the public L AN.
For detailed instructions, see HP StorageWorks HA-Fabric Ma nager User Guide.
If the public LAN IP address of the HAFM appliance is ever changed, this le
must be edited again to reect the new IP address.
Performance graphs inaccurate for time period when HAFM appliance is s hut
down
If the HAFM appliance has b een shut down or the H AFM application and Ser vices have
been stopped, after restarting the performance graphs continue and draw a at line
from the stop point to the n ew start point. This indicates a level of performance d u ring
18