FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks HA-Fabric Manager User Guide (AA-RS2CF-TE, March 2005)

HA-Fabric Manager user guide 209
Could not stop port
diagnostics.
Port diagnostics could not
be stopped by the
Element Manager
because the Ethernet link
is down or busy, or
because the director is
busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Could not write firmware
to flash.
A firmware version could
not be written from the
HAFM appliance to
FLASH memory
Retry the operation again. If the
condition persists, contact the next
level of support.
Control Unit Port (CUP)
name and port name are
identical (FICON ONLY).
Within the address
configuration, one or
more of the port names
are the same as the CUP
name.
Make sure all names are unique
for the ports and CUP name.
Date entered is invalid. The date is entered
incorrectly in the
Configure Date and Time
dialog box. Individual
field entries may be
correct, but the overall
date is invalid (for
example, a day entry of
31 for a 30-day month).
Verify each entry is valid and
consistent.
Device applications
should be terminated
before starting
diagnostics. Press NEXT
to continue.
Port diagnostics
(loopback tests) cannot
be performed on a port
while an attached device
application is running.
Terminate the device application
and perform diagnostics again.
[device WWN] cannot
be removed from the
Switch Membership List
while participating in
Switch Binding. The
device must be isolated
from the switch, or Switch
Binding deactivated
before it can be removed.
You attempted to remove
a device WWN from the
Switch Membership List
(SANtegrity Binding
feature) while Switch
Binding is enabled.
Remove the device from the switch
by blocking the port, setting the
switch offline, or disabling Switch
Binding through the Switch Binding
Change State dialog box before
removing devices from the Switch
Membership List.