R3102-R3103-HP 6600/HSR6600 Routers Interface Command Reference

110
0 Ais Alarm Secs, 2087 Los Alarm Secs
52 Slip Secs, 2087 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 2087 Unavail Secs
Table 18 Command output
Field Descri
p
tion
T1 2/0/0 current state Physical state of the interface: up or down.
Description Description about the T1 interface.
Basic Configuration Basic configurations of the interface.
Work mode
Operating mode of the T1 interface, T1 framed in this
example.
Cable type
Cable type of the T1 interface, 100 ohm balanced in
this example.
Frame-format
Frame format configured on the T1 interface: ESF or
SF.
fdl FDL format: ANSI, ATT, or none.
Line code Line code: AMI or B8ZS.
Source clock
Source clock used by the interface: master for the
internal clock or slave for the line clock.
Data-coding Normal or inverted.
Idle code 0x7E or 0xFF.
Itf type Type of interframe filling tag: 0x7E or 0xFF.
Itf number Number of interframe filling tags.
Loop back
Loopback setting on the interface: local, payload,
remote, or not set.
Alarm State Alarm state.
Receiver alarm state Type of received alarm: none, LOS, LOF, RAI, or AIS.
Transmitter is sending remote alarm. Type of transmitted alarm: RAI, or none.
Pulse density violation detected
The detected pulse density is incompliant with the
specification.
SendLoopCode History:
inband-llb-up:0 times, inband-llb-down:0
times.
fdl-ansi-llb-up:0 times, fdl-ansi-llb-down:0 times.
fdl-ansi-plb-up:0 times, fdl-ansi-plb-down:0 times
History of loopback code sending to the peer end,
including the number of transmissions for each type of
code, and the type of the last sent code. (For more
information, see the sendloopcode command
.)
BERT state:(stopped, not completed)
BERT state: completed, stopped (not completed), or
running.
Test pattern: 2^15, Status: Not Sync, Sync Detected:
0
Test pattern in use (2^20 or 2^15), 2^15 in this
example; synchronization state, and the number of
detected synchronizations.
Time: 0 minute(s), Time past: 0 minute(s) Duration of the BERT test and time that has elapsed.