R3303-HP 6600/HSR6600 Routers Fundamentals Command Reference
180
Syntax
power-supply policy priority priority slot slot-number
undo power-supply policy priority slot slot-number
Default
The power supply priority of a card is 2.
Views
System view
Default command level
3: Manage level
Parameters
priority: Priority value in the range of 1 to 3. The smaller the priority value, the higher the priority of a
card.
slot slot-number: Specifies the slot number of a card.
Usage guidelines
Set a higher power supply priority for the card that is processing or will process critical services, so as to
ensure the power supply to the card when the power supply is insufficient or when the power supply
recovers.
The following matrix shows the command and router compatibility:
Command 6602 HSR6602
6604/6608/6616
power-supply policy
priority
No. No.
Yes on 6604 and 6608 routers with
RSE-X1, MCP-X1, or MCP-X2 MPUs and
6616 routers.
Examples
# Set the power supply priority for the card in slot 1 to 10.
<Sysname> system-view
[Sysname] power-supply policy priority 10 slot 1
reboot
On an 6602, use reboot to reboot the device or the specified card.
On an HSR6602, 6604, 6608, or 6616, use reboot to reboot a card, a subcard, or the whole device.
Syntax
reboot [ slot slot-number [ subslot subslot-number ] ]
Views
User view
Default command level
3: Manage level