R3303-HP 6600/HSR6600 Routers Layer 2 - LAN Switching Configuration Guide

193
Ste
p
Command
Remarks
2. Configure one
class for a foreign
CVLAN and
SVLAN pair.
a. Create a class and enter class view:
traffic classifier tcl-name [ operator
and ]
b. Specify a foreign CVLAN as a match
criterion:
if-match customer-vlan-id vlan-id
c. Specify a foreign SVLAN as a match
criterion:
if-match service-vlan-id vlan-id
d. Return to system view:
quit
Repeat this step to create one class
for each foreign CVLAN and
SVLAN pair.
3. Configure one
SVLAN marking
action for a
CVLAN and
SVLAN pair.
a. Create a traffic behavior and enter
traffic behavior view:
traffic behavior behavior-name
b. Configure an SVLAN marking action
to replace the foreign SVLAN ID with
a local SVLAN ID:
remark service-vlan-id vlan-id
c. Return to system view:
quit
Repeat this step to configure one
SVLAN marking action for each
CVLAN and SVLAN pair.
4. Create a QoS
policy and enter
QoS policy view.
qos policy policy-name N/A
5. Associate the class
with the behavior.
classifier tcl-name behavior behavior-name
Repeat this step to create other
class-behavior associations.
Configuring an uplink policy for the network-side port
The uplink policy on the network-side port modifies the CVLAN ID of incoming traffic.
To configure an uplink policy for the network-side port:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Create one class
for a local SVLAN
and foreign
CVLAN pair.
a. Create a class and enter class view:
traffic classifier tcl-name [ operator
and ]
b. Specify a foreign CVLAN as a match
criterion:
if-match customer-vlan-id vlan-id
c. Specify a local SVLAN as a match
criterion:
if-match service-vlan-id vlan-id
d. Return to system view:
quit
Repeat this step to create one class
for each local SVLAN and foreign
CVLAN pair.