Step5 Use the display boot-loader [ slot slot-number ] command to view the application files to be used by
the active and standby MPUs for booting the system. Make sure the application files are of the same
version.
Step6 After rebooting the standby MPU using the slave restart command in system view, use the display
version command to view the current version of the application files. If the application files have the new
version, you have succeeded in updating the application files on the standby MPU.
Step7 Use the display device command to view the status of the active and standby MPUs. If both MPUs are
in the normal status, the active and standby MPUs are normal.
On a device configured with an RPE-X1
<HP> display device
Slot No. Board type Status Primary SubSlots
---------------------------------------------------------------------
0 N/A Absent N/A N/A
1 FIP-200 Normal N/A 2
2 N/A Absent N/A N/A
3 N/A Absent N/A N/A
4 RPE-X1 Normal Slave 0
5 RPE-X1 Normal Master 0
6 N/A Absent N/A 0
7 N/A Absent N/A N/A
8 FIP-200 Normal N/A 2
9 N/A Absent N/A N/A
On a device configured with an RSE-X1
<HP> display device
Slot No Board type Status Primary SubSlots
---------------------------------------------------------------------
1 RSE-X1 Normal Master 0
2 RSE-X1 Normal Slave 0
3 FIP-110 Normal N/A 4
4 FIP-210 Normal N/A 2
Method 4
Use the copy command to copy the main application file of the active MPU to the standby MPU, specify
the file as the main application file, and reboot the standby MPU. Note that when using this method,
make sure that the main application files of the active and standby MPUs are of the same version.
The detailed steps are as follows:
Step1 Use the dir command to view the application file to be updated on the active MPU:
If any, proceed with operation in Step 2;
If not, upload the application file to the active MPU through Xmodem, FTP, or TFTP. For details about
uploading an application file, refer to the procedures mentioned above.
Step2 Use the dir command to view the available space in the CF card on the standby MPU. Make sure there is
enough space for the new application file.
Step3 Use the copy command to copy the application file on the active MPU to the standby MPU: