R3102-R3103-HP 6600/HSR6600 Routers Interface Command Reference
209
Field Descri
p
tion
BERR PRBS bit error (pseudo-random binary sequence bit error, for test only).
BIP Bit-interleaved parity.
REI Remote error indication.
In this table, FRED, COFA, and SEF are called alarm errors (AERRs).
Examples
# Display the path information of interface CPOS 2/0/0.
<Sysname> display controller cpos 2/0/0
Cpos2/0/0 current state : UP
Description : Cpos2/0/0 Interface
Frame-format SDH, multiplex AU-3, clock master, loopback not set
Tx: J0: 0x01
Rx: J0: 0x01
Regenerator section:
Alarm: none
Error: 0 BIP, 0 SEF
Multiplex section:
Alarm: none
Error: 0 BIP, 0 REI
Higher order path(VC-3-1):
Alarm: none
Error: 0 BIP, 0 REI
Higher order path(VC-3-2):
Alarm: none
Error: 0 BIP, 0 REI
Higher order path(VC-3-3):
Alarm: none
Error: 0 BIP, 0 REI
Cpos2/0/0 CT1 1 is up
Frame-format ESF, clock master, loopback not set
Cpos2/0/0 CT1 2 is up
Frame-format ESF, clock master, loopback not set
Cpos2/0/0 CT1 3 is up
Frame-format ESF, clock master, loopback not set
......
Cpos2/0/0 CT1 83 is up
Frame-format ESF, clock master, loopback not set
Cpos2/0/0 CT1 84 is up
Frame-format ESF, clock master, loopback not set
Table 25 Command output
Field Descri
p
tion
Cpos2/0/0 current state: Current physical state of the CPOS interface.
Description: Interface description.