R3303-HP 6600/HSR6600 Routers Fundamentals Command Reference
172
Field Remarks
RX loss of signal Incoming (RX) signal is lost.
RX not ready RX is not ready.
RX CDR loss of lock RX clock cannot be recovered.
RX power high RX power is high.
RX power low RX power is low.
TX not ready TX is not ready.
TX fault TX fault.
TX CDR loss of lock TX clock cannot be recovered.
TX bias high TX bias current is high.
TX bias low TX bias current is low.
TX power high TX power is high.
TX power low TX power is low.
Module not ready Module is not ready.
APD supply fault APD (Avalanche Photo Diode) supply fault.
TEC fault TEC (Thermoelectric Cooler) fault.
Wavelength unlocked
Wavelength of optical signal exceeds the manufacturer's
tolerance.
Temp high Temperature is high.
Temp low Temperature is low.
Voltage high Voltage is high.
Voltage low Voltage is low.
Transceiver info I/O error Transceiver information read and write error.
Transceiver info checksum error Transceiver information checksum error.
Transceiver type and port configuration
mismatch
Transceiver type does not match port configuration.
Transceiver type not supported by port
hardware
Transceiver type is not supported on the port.
Examples
# Display the alarms existing on the transceiver module in interface GigabitEthernet 3/0/1.
<Sysname> display transceiver alarm interface gigabitethernet 3/0/1
GigabitEthernet3/0/1 transceiver current alarm information:
RX loss of signal
RX power low
Table 31 Command output
Field Descri
p
tion
transceiver current alarm information Alarms existing on the transceiver module.
RX loss of signal Incoming (RX) signal is lost.