R3303-HP 6600/HSR6600 Routers Interface Configuration Guide

50
Ste
p
Command
Remarks
16. Shut down the POS interface.
shutdown
Optional.
By default, a POS interface is up.
When you modify parameters on a
POS interface, execute the
shutdown command, and then the
undo shutdown command to make
your modifications take effect.
NOTE:
If no cable is connected to a physical interface, shut down the interface with the shutdown command to
prevent anomalies caused by interference. Use the shutdown command with caution because once an
interface is shut down, it stops operating.
Enabling sub-interface rate statistics collection for a POS
interface
With sub-interface rate statistics collection enabled for a POS interface, the device refreshes the
sub-interface rate statistics of the POS interface periodically. Use the display command to view the
collected statistics.
To enable sub-interface rate statistics collection for a POS interface:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter POS interface view.
interface pos interface-number N/A
3. Enable sub-interface rate statistics
collection for the POS interface.
sub-interface rate-statistic
Optional.
Disabled by default.
NOTE:
Use this feature cautiously, because it is system resource demanding.
Changing the interface type
You can change the interface type between POS and GE for interfaces on the HIM-TS8P interface
module.
To change the type of an interface:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A