R3102-R3103-HP 6600/HSR6600 Routers Interface Command Reference

152
Frame-format NO-CRC4, clock slave, loopback not set
Receiver alarm state is none
BERT state:(stopped)
E3 2/0/0 CE1 14 is up
Frame-format NO-CRC4, clock slave, loopback not set
Receiver alarm state is none
BERT state:(stopped)
E3 2/0/0 CE1 15 is up
Frame-format NO-CRC4, clock slave, loopback not set
Receiver alarm state is none
BERT state:(stopped)
E3 2/0/0 CE1 16 is up
Frame-format NO-CRC4, clock slave, loopback not set
Receiver alarm state is none
BERT state:(stopped)
e1 bert
Use e1 bert to enable BERT test for an E1 channel created on a CE3 interface.
Use undo e1 bert to disable BERT test.
Syntax
e1 line-number bert pattern { 2^11 | 2^15 | 2^20 | 2^23 | qrss } time number [ unframed ]
undo e1 line-number bert
Default
No BERT test is performed.
Views
CE3 interface view
Default command level
2: System level
Parameters
line-number: E1 channel number, in the range of 1 to 28.
pattern: Specifies BERT test mode, which can be 2^11, 2^15, 2^20, 2^23, and QRSS.
2^11: Specifies the code stream transmitted is the 11th power of 2 bits in length.
2^15: Specifies the code stream transmitted is the 15th power of 2 bits in length.
2^20: Specifies the code stream transmitted is the 20th power of 2 bits in length.
2^23: Specifies the code stream transmitted is the 23rd power of 2 bits in length.
qrss: Specifies the code stream transmitted is the 20th power of 2 bits in length and the number of
successive 0s in the code stream is no more than 14.
time number: Sets the duration (in minutes) of a BERT teat. The number argument is in the range of 1 to
1,440.
unframed: Sets the overhead bits of the padding frames for BERT test.