HP 6600/HSR6600/HSR6800 Router Series Interface Module Guide

27
NOTE:
The MIM-8T1/MIM-8T1-F does not support ISDN PRI.
For the MIM-8T1, if you use the timeslot binding command on the controller T1 interface, the system
automatically creates the corresponding serial interface, on which you can make configurations. The
MIM-8T1-F does not have a controller T1 interface, and a physical interface corresponds to one and
only one serial interface, which is automatically created without the need of additional configuration.
For the appearance and connection of a MIM-8T1/MIM-8T1-F interface cable, see "Connecting a T1
interface cable."
MIM-1CE3
The MIM-1CE3 is a 1-port channelized E3 interface module. It has the following features:
In E3 mode, it transceives and processes high-speed data streams over the E3 channel, and
provides access to E3 data streams.
In CE3 mode, it provides the low-speed access service at N × 64 kbps, where N is smaller than or
equal to 128.
NOTE:
E3 represents the tertiary group rate of the E series in the TDM system, which is 34.368 Mbps.
An E3 channel can be channelized into 16 E1 channels throu
g
h the demultiplex processes of E23 and
E12, with each E1 channel supporting both the E1 and CE1 operating modes. E23 indicates either
E2-to-E3 multiplex or E3-to-E2 demultiplex, and E12 indicates E1-to-E2 multiplex or E2-to-E1
demultiplex. E23 and E12 discussed here represent the demultiplex process.
Front panel
Figure 22 Front panel
(1) Carrier si
g
nal LED (LINK/ACT) (2) TX interface (3) RX interface
(4) Captive screw (5) Loopback/Alarm LED (LP/AL)
LEDs
Table 31 LED description
LED Status Descri
p
tion
LINK/ACT
Off No carrier signals are received.
On Carrier signals are received.
Flashing Data is being transmitted or received.