HP Comware 5 Debug Manual Vol 2

Default command level
1: Monitor level
Parameters
all: Specifies all types of IRF topology collection debugging.
error: Specifies topology collection error debugging.
event: Specifies topology collection event debugging.
notify: Specifies topology notification debugging. This keyword is reserved for future use.
packet: Specifies topology collection packet debugging.
state: Specifies topology collection state debugging. This keyword is reserved for future use.
timer: Specifies topology collection timer debugging. This keyword is reserved for future use.
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number
argument represents the IRF member ID. The slot-number argument represents the slot number of the card.
Usage guidelines
Table 1 describes output fields and messages for the debugging stm topology error command.
Table 161 Output from the debugging stm topology error command
Field
Description
Command: command Control command.
irf-port: irf-port
The IRF port that sent or received the hello packet:
1IRF-port 1.
2IRF-port 2.
Ret: ret Return value.
Ver: version STM version.
Set cfg failed. Ret: ret, dest-memberid: member-id
Configuration failed. The source and destination
nodes are displayed.
Set drv link delay failed. Ret: ret Link delay failed to be set in the driver.
Set irf-port failed. Ret: ret, irf-port: irf port, cmd:
command
STM failed to disable the IRF port or failed to cancel
the operation of disabling the IRF port.
RPC callback receive data point is null
The receive data pointer of the RPC callback function
is null.
Set member id to drv failed. Ret: ret Member ID failed to be set in the driver.
Set priority to drv failed. Ret: ret IRF member priority failed to be set in the driver.
Set irf-port to drv failed. Ret: ret IRF port settings failed to be set in the driver.
Set debug switch failed. Ret: ret STM failed to configure the debugging switch.
Writing queue failed. Message: Clear counter,
Irf-port: irf port
STM failed to write the hello counter reset message to
the message queue.
The packet version is different, Ver: version STM packet versions are different.
Topo database failed to process the link down event..
Ret: ret
The topology database failed to process the link down
event. This message indicates a topology database
error.
250