HP Comware 5 Debug Manual Vol 2
#
domain default enable system
#
local-user pad2
password simple 2
service-type pad
level 3
#
interface Serial2/0
link-protocol x25
x25 x121-address 2
#
user-interface vty 0 4
authentication-mode scheme
user privilege level 3
#
return
<Sysname> debugging pad
*0.685313091 Sysname X25/7/debug2:
PAD0: Receive a control packet
*0.685313092 Sysname X25/7/debug2:--Packet is Read PAD message
// Router A received from Router B a PAD control packet asking for the X.3 parameters of Router A.
*0.685313092 Sysname X25/7/debug2:
PAD0: Send a control packet
*0.685313092 Sysname X25/7/debug2:--Packet is parameter indication PAD message
*0.685313093 Sysname X25/7/debug2:
X.3 parameter is:
*0.685313093 Sysname X25/7/debug2: 1:1 2:0 3:2 4:1 5:0 6:0 7:21 8:0
*0.685313093 Sysname X25/7/debug2:
**************************************************************************
* All rights reserved (2004-2006) *
* Without the owner's prior written consent, *
* no decompiling or reverse-engineering shall be allowed. *
**************************************************************************
*0.685313290 Sysname X25/7/debug2: 9:0 10:0 11:14 12:0 13:0 14:0 15:0 16:127
*0.685313290 Sysname X25/7/debug2:
*0.685313291 Sysname X25/7/debug2: 17:21 18:18 19:0 20:0 21:0 22:0
*0.685313490 Sysname X25/7/debug2:
// Router A responded with a PAD control packet carrying the local X.3 parameters.
PAD0: Receive a user data packet,Length:402
*0.685313490 Sysname X25/7/debug2:
PAD0: Receive a user data packet,Length:28
*0.685313491 Sysname X25/7/debug2:
PAD0: Receive a user data packet,Length:11
*0.685313690 Sysname X25/7/debug2:
312