HP Comware 5 Debug Manual Vol 2
x25 switching
#
interface Ethernet1/0
ip address 2.2.2.2 255.255.255.0
#
interface Serial2/0
link-protocol x25 dce
#
x25 switch svc 2 interface Serial2/0
x25 switch svc 1 xot 2.2.2.1
#
Configuration on Router D:
<Sysname> display current-configuration interface serial 2/0
#
interface Serial2/0
link-protocol x25
x25 x121-address 2
x25 map ip 1.1.1.1 x121-address 1
ip address 1.1.1.2 255.255.255.0
#
# Enable XOT packet and event debugging on Router B.
<Sysname> debugging x25 xot event
*0.468328 Sysname X25/7/debug2:
XOT: from local 2.2.2.1:1024 connect to 2.2.2.2:1998 successfully !
*0.468407 Sysname X25/7/debug2:
// An XOT connection was successfully established between interface Ethernet 1/0 on Router B and
interface Ethernet 1/0 on Router C.
XOT: Serial2/0-2.2.2.2-1024 I Data Length is 5
*0.468438 Sysname X25/7/debug2:
// Router B received a packet through the XOT connection.
XOT: Serial2/0-2.2.2.2-1024 O Data Length is 128
*0.468438 Sysname X25/7/debug2:
XOT: Serial2/0-2.2.2.2-1024 O Data Length is 6
*0.468500 Sysname X25/7/debug2:
XOT: Serial2/0-2.2.2.2-1024 I Data Length is 3
*0.468532 Sysname X25/7/debug2:
XOT: Serial2/0-2.2.2.2-1024 I Data Length is 128
*0.468532 Sysname X25/7/debug2:
XOT: Serial2/0-2.2.2.2-1024 I Data Length is 6
*0.468563 Sysname X25/7/debug2:
XOT: Serial2/0-2.2.2.2-1024 O Data Length is 3
// Router B sent packets through the XOT connection.
NOTE
:
The
debugging x25 xot command only provides limited debugging information. For more accurate
analysis, you need to also enable X.25 packet or event debugging in addition to obtain adequate
information.
323