HP Comware 5 Debug Manual Vol 3

Field
Description
invalid index index in real time on slave board
Invalid RMON table entry index was found on the
standby MPU during real-time backup.
indexIndex of an RMON table entry.
etherStatsEntry index aged at
time-hour:time-minute:time-second in real time on
slave board
The Ethernet statistics entry aged out during real-time
data backup on the standby MPU.
historyControlEntry index aged at
time-hour:time-minute:time-second in real time on
slave board
The history control entry aged out on the standby
MPU.
eventEntry index aged at
time-hour:time-minute:time-second in real time on
slave board
The event entry aged out during real-time data backup
on the standby MPU.
alarmEntry index aged at
time-hour:time-minute:time-second in real time on
slave board
The alarm entry aged out during real-time data
backup on the standby MPU.
prialarmEntry index aged at
time-hour:time-minute:time-second in real time on
slave board
The private alarm entry aged out during real-time data
backup on the standby MPU.
the port-removed flag of etherStatsEntry index
changed to false for interface-inserted event at
time-hour:time-minute:time-second in real time on
slave board
The port-removed flag of the Ethernet statistics entry
on the standby MPU changed to false because an
interface card was inserted during real-time data
backup.
the port-removed flag of historyControlEntry index
changed to false for interface-inserted event at
time-hour:time-minute:time-second in real time on
slave board
The port-removed flag of the history control entry on
the standby MPU changed to false because an
interface card was inserted during real-time data
backup.
failed to recover data in real time on slave board
The standby MPU failed to restore data during
real-time backup.
etherStatsEntry index aged at
time-hour:time-minute:time-second
Removal of an Ethernet interface can cause its Ethernet
statistics entry to age out.
historyControlEntry index aged at
time-hour:time-minute:time-second
A history control entry typically ages out because its
bucket is full or its timer expires.
synchronous RPC timeout in sampling statistics at
interface-name for historyControlEntry index
RPC call timed out when RMON was sampling data
on the Ethernet interface for the history control entry.
failed to call RPC synchronously (errCode: error-code)
in sampling statistics at interface-name for
historyControlEntry index
A synchronous RPC call failed when RMON was
sampling data on the Ethernet interface for the history
control entry.
sample no statistics at interface-name for
historyControlEntry index by synchronous RPC
RMON performed a synchronous RPC call to sample
statistics for the history control entry on the Ethernet
interface, but the call did not collect any statistics.
synchronous RPC timeout in sampling statistics at
interface-name for etherStatsEntry index
Synchronous RPC call timed out when RMON
sampled statistics on the Ethernet interface for the
Ethernet statistics entry.
failed to call RPC synchronously (errCode: error-code)
in sampling statistics at interface-name for
etherStatsEntry index
A synchronous RPC call failed when RMON was
sampling data on the Ethernet interface for the
Ethernet statistics entry.