HP Comware 5 Debug Manual Vol 3
// The SSA module received a REGISTER request from the protocol stack.
*Sep 7 16:51:40:326 2007 Sysname SSM/7/VOICE:
SSM_PRIM [REG_SSA]:
Send UCM Register request message.
// The SSA module sent the REGISTER request to the UCM module.
*Sep 7 16:51:40:327 2007 Sysname SSM/7/VOICE:
SSM_PRIM [REG_SLC]:
Receive UCM Register request message.
// The SLC module received the REGISTER request from the UCM module.
*Sep 7 16:51:40:327 2007 Sysname SSM/7/VOICE:
SSM_INFO [REG_SLC]:
General: Succeed in getting a free element from the list.
Additional: Register control block ID is 33.
// The SLC module got a free element from the list.
*Sep 7 16:51:40:327 2007 Sysname SSM/7/VOICE:
SSM_EVENT [REG_SLC]:
REGISTER: Received event UCMREGISTERREQ while at state IDLE.(ObjectID = 33)
// The SLC module received a UCMREGISTERREQ event in the IDLE state.
*Sep 7 16:51:40:328 2007 Sysname SSM/7/VOICE:
SSM_FSM [REG_SLC]:
REGISTER: State changed from IDLE to REGISTERING.(ObjectID = 33)
// The SLC module changed from IDLE state to REGISTERING state.
*Sep 7 16:51:40:328 2007 Sysname SSM/7/VOICE:
SSM_INFO [REG_SLC]:
General: Succeed in dealing with register request.
Additional: Status code is 401.
expires is 3600(s).
user number is 3001.
// The SLC module handled the registration request successfully.
*Sep 7 16:51:40:328 2007 Sysname SSM/7/VOICE:
SSM_PRIM [REG_SLC]:
Send UCM Register response message.
// The SLC module sent a REGISTER response to the UCM module.
*Sep 7 16:51:40:328 2007 Sysname SSM/7/VOICE:
SSM_TIMER [REG_SLC]:
Start Timer: Type = 2, Group = 2, Index = 33, Length = 64000
// The SLC module started a timer, with the value set to 64000 ms.
368