HP Comware 5 Debug Manual Vol 3
%Jul 6 17:31:42:812 2006 PE1 IFNET/5/LINK UPDOWN:
Vlan-interface80: link status is UP
[PE1-Vlan-interface80]
[PE1-Vlan-interface80]
[PE1-Vlan-interface80]
[PE1-Vlan-interface80]
[PE1-Vlan-interface80] interface vlan-interface 10
[PE1-Vlan-interface10] display this
#
interface Vlan-interface10
ip address 100.1.1.1 255.255.255.0
mpls
mpls ldp
#
return
[PE1-Vlan-interface10] undo mpls
[PE1-Vlan-interface10]
#Jul 6 17:32:16:469 2006 PE1 LDP/5/SessionDown: Session(22.22.22.22:0. public Instance)'s
state change to Down
*0.2345547 PE1 L2V/8/DBG:
! L2VPN CCC :Invalid Remote interface - not able to get the outifindex
*0.2345547 PE1 L2V/8/DBG:
! L2VPN CCC :Invalid Remote interface - not able to get the outifindex
*0.2345766 PE1 L2V/8/DBG:
! L2VPN CCC :Invalid Remote interface - not able to get the outifindex
*0.2345984 PE1 L2V/8/DBG:
! L2VPN CCC :Invalid Remote interface - not able to get the outifindex
*0.2346203 PE1 L2V/8/DBG:
! L2VPN CCC :Invalid Remote interface - not able to get the outifindex
*0.2346422 PE1 L2V/8/DBG:
! L2VPN CCC :Invalid Remote interface - not able to get the outifindex
*0.2346641 PE1 L2V/8/DBG:
! L2VPN CCC :Invalid Remote interface - not able to get the outifindex
// Invalid remote interface was not able to get the outgoing interface index.
# Enable debugging for MPLS L2VPN events. Output similar to the following example is generated when
these tasks are performed:
•
Connect three routers that are directly connected.
•
Configure MPLS, MPLS LDP and Martini settings on each router, and establish a Martini connection
between two PE routers.
•
Execute the debugging mpls l2vpn event command on one PE router.
•
Disable the MPLS function on the interface that is connected to the private network.
[PE1]
[PE1] display mpls l2vc
total ldp vc : 1 1 up 0 down
Transport Client VC Local Remote Tunnel
VC ID Intf State VC Label VC Label Policy
46