R3303-HP HSR6800 Routers Fundamentals Command Reference

140
<Sysname> display alarm
Chassis Slot Level Info
1 6 ERROR Fan 2 is absent.
1 6 ERROR Power 2 is absent.
1 6 ERROR The board in slot 10 is faulty.
2 3 WARNING The temperature of sensor 3 exceeds the lower limit.
display clock
Use display clock to display the system time and date.
Syntax
display clock [ | { begin | exclude | include } regular-expression ]
Views
Any view
Default command level
1: Monitor level
Parameters
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Usage guidelines
The current system time and date are decided by the clock datetime, clock summer-time one-off, or clock
summer-time repeating, and clock timezone commands. For more information about how the system
time and date are decided, see Fundamentals Configuration Guide.
Examples
# Display the system time and date.
<Sysname> display clock
09:41:23 UTC Thu 12/15/2005
Related commands
clock datetime
clock summer-time one-off
clock summer-time repeating
clock timezone
display configure-user
Use display configure-user to display the users that have logged in to the device but are not in user view.